334
Abstract Views
815
PDF Download
Original Research

Differences in blood creatinine levels using mono reagent which was checked immediately and which was delayed for 5 hours at room temperature

, ,
Pages 50-54

Abstract

Reagents used for examination must be considered for stability. Reagents made beforehand must be used immediately because the reagent that has been opened has a shorter stability period than the reagent that has not been opened. This study aims to determine the difference in creatinine levels using a mono reagent that is immediately used and which is left in for 5 hours at room temperature. This research is a pre-experimental study with a one-group pretest-posttest research design. The research sample was the remaining serum of the patients who were examined in the laboratory of Medika Sangatta Hospital as many as 40 samples. The test results were analyzed descriptively and statistically using paired sample t-test. The results of the descriptive test showed that the difference between the mean creatinine levels using immediate reagent and those experiencing indentation for 5 hours was 0.1 with the maximum value of creatinine levels using immediate reagent and those experiencing indwelling were 1.7 mg/dl and 1.6 mg/dl. While the minimum values ??are 0.9 mg / dl and 0.8 mg / dl (p=0.003). There was a difference in creatinine levels using a mono reagent which is immediately used and which has been left standing for 5 hours at room temperature so the mono reagent that has been made should be used immediately.

There is no Figure or data content available for this article

References

  • Indonesia P. Peraturan Menteri Kesehatan Republik Indonesia Nomor 411/MENKES/PER/III/2010 Tentang Laboratorium Klinik.; 2010.
  • Airasian P.W MG dan GLR. Educational Research: Compentencies for Analysis and Application.; 2012.
  • UGM BPKFK. Pemantapan Mutu Internal Laboratorium Kinik.; 2010.
  • Indonesia P. Peraturan Menteri Kesehatan Republik Indonesia Nomor 43 Tahun 2013 Tentang Cara Penyelenggaraan Laboratorium Klinik Yang Baik.; 2013.
  • Corwin EJ. Buku Saku Patofisiologi Corwin. Aditya Media; 2009.
  • RI D. Pedoman Pencampuran Obat Suntik DanPenanganan Sediaan Sitostatika.; 2009.
  • Dwiningsih. Perbedaan Kadar Kreatinin berdasarkan Penyimpanan Reagen pada Suhu 4oC dan Suhu Kamar. Skripsi. Published online 2018.
  • Hardjoeno. Interpretasi Hasil Tes Laboratorium Diagnostik.; 2003.
  • Infolabmed. Index Interferensi. Published online 2017. http://www.infolabmed.com/2017/03/download-pdfindex-interferensi.html. Diunduh pada tanggal 27 Februari 2021
  • Insert Kit. Creatinin FS. Diasys Daignostic System GmbH; 2019.
  • Indonesia KKR. Pedoman Interpretasi Data Klinik. Direktorat Jenderal Bina Kefarmasian Dan Alat Kesehatan.; 2011.
  • M P. Exploring the Iceberg of Errors in Laboratory Medicine. Acta; 2009.
  • Notoatmodjo S. Metodologi Penelitian Kesehatan. Rineka Cipta; 2010.
  • Praptomo A. Pengendalian Mutu Laboratorium Medis. Penerbit Deepublish; 2018.
  • Raharjo, S.B. BS dan HN. Perbedaan Kadar Total Protein Dalam Serum Menggunakan Reagen Biuret Yang Diletakkan Dalam Alat Kimia Analyzer Segera, 24 Jam, 48 Jam Dan 72 Jam.; 2017.
  • Sukma Hanggara D. Mengatasi Masalah Ikterik pada Spesimen Serum. Published online 2018.
  • Rinda AS. Pengaruh Konsentrasi Asam Pikrat pada Penentuan Kreatinin menggunakan Sequntial Injection Analysis. Kim Student J. 2015;1(1):1-5.
  • Sugiyono. Satistika Untuk Penelitian Cetakan Kelima.; 2003.
  • Sacher, Ronald A. RAM. Tinjauan Klinis Hasil Pemeriksaan Laboratorium. EGC; 2004.
There is no Supplemental content for this article.

How to Cite This

Nurhidayati, N., Hardisari, R., & Nuryati, A. (2021). Differences in blood creatinine levels using mono reagent which was checked immediately and which was delayed for 5 hours at room temperature. PUINOVAKESMAS, 2(2), 50–54. https://doi.org/10.29238/puinova.v2i2.1173

Article Metrics

Download Statistics

Downloads

Download data is not yet available.

Other Statistics

Verify authenticity via CrossMark
Copyright and permissions information is unavailable

Data Availability