Effectiveness of class 1 biological safety cabinet modification on reducing air germ rate

, , ,
Pages 27-31

Abstract

Biological Safety Cabinet (BSC) in the form of a ventilated cupboard using a combination of High-Efficiency Particulate Air (HEPA) filtration system, laminar airflow, and containment to protect laboratory, product, and the environment from harmful biological agents. This research aims to determine the effect of level 1 BSC created to decrease the number of air germs in the laboratory. This study was an observational analytic using a cohort design. The research object is the number of air germs in standard Level 1 BSC Safe-tech ES 199 models and level 1 BSC created from a team in the laboratory. Data analysis using one-way ANOVA and independent t-test. One-way ANOVA test data shows the standard level 1 BSC Safe-tech ES 199 models and the creation of level 1 BSC used in 60 minutes and 90 minutes is the same as significant (p>0.05), while the duration of use for 120 minutes has a significant difference (p<0.05). Independent t-test analysis showed Sig (2-tailed) = 0.577, so there were no differences between the two tools during the 120-minute use. The creation of level 1 BSC can reduce the number of air germs.

There is no Figure or data content available for this article

References

  • Pratiwi UH. Analisis Implementasi Biosafety Di Laboratorium Klinik RSUD Tugurejo Semarang.; 2008.
  • WHO. Laboratory Biosafety Manual Third Edition.; 2004.
  • Redjeki S. Kesehatan Dan Keselamatan Kerja.; 2016.
  • Suhardi, Sri H., Koesnandar, Dwi K. I. HA. Biosafety?: Pedoman Keselamatan Kerja Di Laboratorium Mikrobiologi Dan Rumah Sakit.; 2008.
  • Arifin A. Isolasi Dan Identifikasi Bakteri Di Lingkungan Laboratorium Mikrobiologi Klinik RSUDZA Banda Aceh. Vol 1(4).; 2016.
  • Olazaran SM, Otera RM, Noriega ER, Diaz JL, Trevino SF, Gonzales GG et al. Microbiological and Molecular Characterization of Staphylococcus Hominis Isolates from Blood. Vol 8(4).; 2013.
  • RI D. Permenkes RI No. 1204/Menkes/SK/X/2004 Tentang Persyaratan Kesehatan Lingkungan Rumah Sakit.; 2014.
  • Notoatmodjo S. Metodologi Penelitian Kesehatan.; 2010.
  • Pradika I. Metode Pengambilan Sampel Air?: Lifepatch. Published online 2014. http://lifepatch.org/Metode_Pengambilan _Sampel_Air.htm
  • Cahyono T. Penyehatan Udara. Andi; 2017.
  • ASHRAE. ASHRAE Handbook HVAC-Applications SI Edition. Published online 2011.
  • Office B in M and BLUSGP. U.S. Department of Health and Human Services, Central for Disease Control and Prevention.; 2009.
  • Harding A. dan KBB. Biological Safety. J Clin Pathol. Published online 2006:53–77.
  • Harper, C., R. J. Emery and DMC. An Assessment of Occupational Exposures to Ultraviolet Radiation from Transilluminator Light Boxes in The Course of Biomedical Research Procedures. J Chem Heal Saf. 2008;15(2):16-22.
  • Handoyo B. Kemenkes, Pengaruh Alat “Germ-Uvc-Kill Air Steriliser” Terhadap Angka Kuman Udara Di Puskesmas Karanggayam 1 Kabupaten Kebumen Tahun 2017. Vol Skripsi.; 2017.
There is no Supplemental content for this article.

How to Cite This

Setiawan, B., Febriana, B. A., Martono, B., & Putro, S. (2021). Effectiveness of class 1 biological safety cabinet modification on reducing air germ rate. PUINOVAKESMAS, 2(1), 27–31. https://doi.org/10.29238/puinova.v2i1.1073

Article Metrics

Download Statistics

Downloads

Download data is not yet available.

Other Statistics

Verify authenticity via CrossMark
Copyright and permissions information is unavailable

Data Availability